Platform |
ConnectPort® TS 8 |
ConnectPort® TS 16 |
Performance |
Management |
HTTP/HTTPS, CLI or Telnet; Optional secure enterprise management
via Digi Connectware Manager |
Protocols |
IPv4/IPv6, UDP/TCP, DHCP, Extended Telnet RFC 2217, Telnet,
Reverse Telnet, Modbus to Modbus/TCP protocol conversion support |
Software |
Device-initiated patented RealPort COM port redirector and RFC
2217; Python scripting; Custom development environment |
Status LEDs |
Serial: Tx/Rx; Ethernet: Link/Activity |
Dimensions (L x W x H) |
4.15 in x 7.7 in x 1.3 in (10.5 cm x 19.6 cm x 3.3 cm) |
17 in x 6.95 in x 1.62 in (43.18 cm x 17.65 cm x 4.1 cm) |
Weight |
4.1 lb (1.86 kg) |
5 lb (2.3 kg) |
Security |
SSL, SSL/TLS, SSHv2, FIPS 197 (serial ports), SNMPv2,
PPP |
Interfaces |
Serial |
Ports |
8 RS-232/422/485 serial ports (software selectable) |
16 RS-232 serial ports |
Throughput |
Up to 230 Kbps |
Signal Support |
TXD, RXD, RTS, CTS, DTR, DSR, DCD |
Ethernet |
Physical Layer |
10/100 Base-T |
Data Rate |
10/100 Mbps |
Mode |
Full or Half duplex |
USB |
Ports |
2 ports @ .5A max per port |
Performance |
Power Input |
9-30 VDC @ .8A max |
100-240 VAC, 50-60 Hz, 0.4A |
Power Supply |
12VDC power supply for 0° C to 60° C (32° F to 140° F) with locking barrel
connector included; Extended temperature power supply available |
Open frame power supply: 100 to 250 VAC in 12 VDC out |
Power Consumption |
Typical: 6 W (500mA @ 12Vdc) Max: 12 W (1A @ 12 Vdc) |
Typical: 8 W (660mA @ 12 Vdc) Max: 15 W (1.25A @ 12 Vdc) |
Surge Protection |
4 kV burst (EFT) per-4-4; 2 kV surge per EN61000-4 |
1 kV burst (EFT) per EN61000-4-4; 2 kV surge transient per |
Environmental |
Operating Temperature |
0° C to 60° C (32° F to 140° F) |
0° C to 55° C (32° F to 131° F) |
Storage Temperature |
-40° C to 85° C (-40° F to 185° F) |
Relative Humidity |
5 to 95% (non-condensing) |
Ethernet Isolation |
1500VAC min per IEEE 802.3/ABSU X 3.263 |
Serial Port Protection (ESD) |
+8 kV air gap and +4 kV contact discharge per IEC
1000-4-2 |
Approvals |
Safety |
UL60950-1, EN/IEC 60950-1, CAN/CSA C22.2 No. 60950,
CUL60950-1-03 |
Emissions/Immunity |
FCC Part 15 Subpart B Class A, EN55024, EN55022, Class B, AS/NZS
CUSOR 22, EN61000-3-2 ,3 |